Capacitive Single Circuit of Fluorescent Lamps - Elektrotechnik von A - Z

Hauptmenü

  • Basic knowledge
    • The 5 Safety Rules
    • Dangers of Electrical Current
    • Correctly Wiring Junction Boxes
    • Polarity of Sockets and Couplings
    • Installation Cable Colors and their Specifications
    • Installations - Wires - Colors and their Meaning
    • IP Protection Rating
    • IP Protection Classes
    • Protective Measures
    • Electrical Engineering Terminology
    • Electrical Safety Guidelines and Precautions
  • Circuits
    • Two-Way Switching Circuit
    • Cost-Saving Two-Way Switching Circuit
    • Three-way Switch Circuit
    • Control Three-way Switch Circuit
    • Pushbutton Circuit
    • Dual Circuit of Fluorescent Lamps
    • Inductive Single Circuit of Fluorescent Lamps
    • Capacitive Single Circuit of Fluorescent Lamps
  • Contactor Circuits
    • Star-Delta Starting Contactor Circuit
    • Dahlander Contactor Circuits
    • Reversing Contactor Circuit
    • Self-latching Contactor Circuit
  • Switching Devices
    • Two-way switch
    • Series switch
    • Control-changeover switch
    • Three-way switch
    • Push button
    • Series push button
    • Motion Sensor
    • Dimmer
    • Timer Switch
  • Electrical Equipment
    • The Residual Current Device (RCD)
    • Connecting Electrical Outlets
    • Connecting plug / socket
    • Connecting Lamps
    • CEE Sockets
    • Electric stove in three-phase operation
    • Connecting Telephone Sockets
  • Testing and Measurements
    • Insulation Resistance Measurement
    • Loop Impedance Measurement
    • Residual Current Measurement (RCD Testing)
    • Voltage Measurement
    • Phase Sequence Measurement (in three-phase systems)
    • Protective Conductor Testing
 

Select your language

  • You are here:  
  • Homepage
  • ⇨
  • Circuits
  • ⇨
  • Capacitive Single Circuit of Fluorescent Lamps

Capacitive single connection of fluorescent lamps

Instructions for Wiring and Testing a Capacitive Single Circuit for Fluorescent Lamps

The capacitive single circuit is a special type of circuit used for lighting with fluorescent lamps. Unlike the DUO circuit, only a single fluorescent lamp is operated, which is connected through a capacitive ballast (choke coil).

The purpose of the capacitive single circuit is to make the operation of the fluorescent lamp efficient and flicker-free. The capacitive ballast compensates for the phase shift of the current that typically occurs in fluorescent lamps. This results in a consistent power supply and prevents flickering and the stroboscopic effect.

 

Structure and Function of a Capacitive Single Circuit for Fluorescent Lamps:

The capacitive single circuit enables the operation of a single fluorescent lamp. The lamp is operated through a capacitive ballast, known as a choke coil. The choke coil is used to limit the flow of current and compensate for the phase shift.

 

 

The construction of a capacitive single circuit is quite simple, as only one lamp and one ballast are required. The choke coil is connected in series with the fluorescent lamp, limiting the flow of current to operate the lamp efficiently and without flickering.

 

Functional testing of a capacitive single circuit.

To ensure that the capacitive single circuit functions properly, it is recommended to perform a thorough functional test. You can follow these steps:

 

 

Check the wiring. Make sure that the circuit is wired correctly and that all components are properly connected.

 

Turn on the power supply. Switch on the power supply and observe if the fluorescent lamp ignites properly. Ensure that it operates without flickering or delays.

 

Check for flicker-free operation. During operation, ensure that the fluorescent lamp is flicker-free. Flickering light may indicate faulty wiring.

 

Avoid the stroboscopic effect. Ensure that there is no stroboscopic effect during operation. Such an effect can occur due to incorrect wiring or defective components.

 

Circuit Diagram of a Capacitive Single Circuit for Fluorescent Lamps

 

 

Wiring of a Capacitive Single Circuit for Fluorescent Lamps:

The wiring of a capacitive single circuit requires proper connection of individual components. The following steps should be followed to ensure smooth operation:

 

  • Connect the fluorescent lamps to the ballasts.
    The fluorescent lamps should be connected to the corresponding ballasts according to the wiring diagrams. Ensure that the correct connections are used to compensate for the phase shift.

  • Parallel connection of the ballasts.
    After the fluorescent lamps are properly connected, the ballasts should be connected in parallel. This means that the inputs of all ballasts are connected together, as well as the outputs. This ensures that the current is evenly distributed among the lamps.

  • Connection to the power supply:
    Now connect the parallel-connected ballasts to the power supply. Pay attention to a secure and reliable connection. It is recommended to interrupt the power supply before checking to minimize the risk of electric shocks.

 

 

Careful wiring ensures not only smooth operation of the capacitive single circuit but also the safety of all users. Therefore, do not forget to thoroughly check all connections before commissioning the circuit.

 

Please note that this is a general guide. For specific information and detailed wiring diagrams, refer to the manufacturer's documentation or seek expert assistance.

 

 

Functional Testing of a Capacitive Single Circuit for Fluorescent Lamps:

To ensure that the capacitive single circuit functions properly, it is recommended to perform a thorough functional test. This ensures not only proper wiring but also optimal performance. Below is a step-by-step guide for the functional testing of the capacitive single circuit.

 

  • Start by checking the wiring of the capacitive single circuit. Carefully inspect all connections to ensure they are properly connected. Incorrect wiring can cause malfunctions. It is advisable to turn off the power supply before conducting the check to avoid potential hazards.

  • After checking the wiring, you can turn on the power supply. Observe whether the fluorescent lamps ignite properly. Flickering light or insufficient ignition may indicate problems and should be further investigated. If such issues occur, it is recommended to recheck the wiring.

  • In addition to checking the ignition, it is important to measure the power factor. A high power factor close to 0.95 indicates efficient energy utilization by the circuit. A suitable measuring device can be used for this purpose. If the measured value deviates significantly from 0.95, it may indicate a faulty circuit.

 

If any issues arise during the functional test, you should identify possible sources of errors. Recheck the wiring to ensure that all components are correctly connected.

Also, pay attention to the polarity of the connections. Furthermore, it may be helpful to test the functionality of the lamps used. Replace any defective lamps if necessary.

By carefully conducting the functional test, you can ensure that the capacitive single circuit operates flawlessly and achieves optimal results. Regularly check the functionality to detect and resolve potential issues early on.

 

Advantages and Disadvantages of a Capacitive Single Circuit for Fluorescent Lamps:

The capacitive single circuit offers several advantages. Firstly, it enables an economical lighting system by improving power factors and optimizing energy consumption.

 

Secondly, it ensures flicker-free and instant ignition of fluorescent lamps, enhancing visual comfort. Furthermore, it eliminates humming and the stroboscopic effect, resulting in pleasant and stable lighting.

 

Advantages of a Capacitive Single Circuit:

  • Improved performance. A capacitive single circuit provides several advantages over conventional circuits. It allows for enhanced performance and efficiency by using two separate circuits to evenly distribute the load. This enables more effective energy utilization, leading to higher performance.

  • Flicker-free and instant ignition of fluorescent lamps. Thanks to the capacitive single circuit, flickering and delays in lamp ignition are avoided. This ensures immediate and reliable lighting without any disruptive effects.

  • No humming. Unlike some other circuit types, the capacitive single circuit does not cause humming or other disturbing noises. The lighting remains quiet and pleasant.

  • No stroboscopic effect. The use of a capacitive single circuit eliminates the stroboscopic effect that may occur with certain fluorescent lamps.

 

 

Disadvantages of a Capacitive Single Circuit:

  • Complexity and cost. A capacitive single circuit is generally more complex in design compared to conventional circuits. This can result in higher costs for development, implementation, and maintenance. Additionally, special components or devices may be required to support the functionality of the capacitive single circuit. These additional costs should be considered when deciding on a capacitive single circuit.

  • Space requirement. Due to the use of two separate circuits, a capacitive single circuit typically requires more space than a conventional circuit. This can be a concern when space is limited, such as in compact electronic devices or systems. Therefore, the space requirement should be taken into account during system planning and design.

  • Compatibility issues. When using a capacitive single circuit, compatibility issues may arise between the two circuits. Different voltages, frequencies, or signal levels can affect functionality or cause interference. Therefore, it is important to carefully consider compatibility when selecting and integrating components and identify potential issues early on.

Despite some potential disadvantages, the capacitive single circuit for fluorescent lamps offers improved efficiency and provides pleasant lighting without any disruptive effects. It is important to consider the specific requirements and conditions of the system to decide whether a capacitive single circuit is the right choice.

 

Comparison: Conventional Ballast vs. Electronic Ballast

In the lighting industry, conventional ballasts are increasingly being replaced by electronic ballasts (EBs). This development is due to the numerous advantages offered by EBs.

A key advantage of EBs is their improved energy efficiency. With higher frequencies, they convert electricity more efficiently and reduce energy losses compared to conventional ballasts. This results in lower energy consumption, reducing costs and promoting environmental friendliness.

 

Another important aspect is the flicker-free light produced by EBs. Unlike conventional ballasts, fluorescent lamps operated with EBs start instantly and without visible flickering. This flicker-free illumination significantly enhances visual comfort and reduces eye strain, especially during prolonged use.

Additionally, EBs contribute to the extended lifespan of fluorescent lamps. With smoother and gentler operation, the lamps experience less stress, leading to increased durability. As a result, they require less frequent replacement, saving costs and effort.

 

EBs also offer greater flexibility. They often come with additional features such as dimming capability and the ability to connect various types of fluorescent lamps. This enables precise adjustment of the lighting to specific requirements and provides more control over the lighting environment.

Last but not least, EBs are advantageous from an ecological perspective. With their higher energy efficiency and longer lamp lifespan, they contribute to reducing energy consumption and waste generation. The use of EBs is therefore a step towards sustainability and environmental protection.

 

Overall, electronic ballasts are an advanced and recommended alternative to conventional ballasts. Their advantages in terms of energy efficiency, flicker-free light, extended lamp lifespan, flexibility, and environmental friendliness make them the preferred choice for fluorescent lamp lighting. By employing EBs, companies can reduce costs, enhance comfort, and contribute to environmental conservation.

Electronic Ballast (EB)

 

 

 

 

Elektrosicherheit: Richtlinien und Vorsichtsmaßnahmen für einfache elektrotechnische Arbeiten

 

Die Sicherheit hat oberste Priorität.

  • Alle hier bereitgestellten Anleitungen und Informationen dienen rein informativen Zwecken und sollen ausschließlich zur Informationsbeschaffung und Weiterbildung verwendet werden. Sie sollten nicht als Ersatz für professionelle Beratung angesehen werden. Bei Zweifeln empfiehlt es sich, einen qualifizierten Elektriker hinzuzuziehen, um fachkundige Unterstützung zu erhalten.

  • Es ist wichtig, die örtlichen Vorschriften und Bestimmungen bei elektrischen Arbeiten zu beachten. Arbeiten mit Strom sollten nur von qualifizierten Fachleuten durchgeführt werden, da sie lebensgefährlich sein können.

  • Fehler in Anleitungen und Schaltbildern sind möglich. Der Anbieter übernimmt keine Gewähr oder Haftung für Schäden oder Verletzungen, die aus der Umsetzung der bereitgestellten Informationen resultieren könnten. Es liegt in Ihrer Verantwortung, die Richtigkeit der Informationen zu überprüfen und die erforderlichen Sicherheitsvorkehrungen zu treffen.

  • Die Verwendung geeigneter persönlicher Schutzausrüstung (PSA) ist entscheidend, um die Sicherheit bei elektrotechnischen Arbeiten zu gewährleisten. PSA schützt vor Stromschlägen, Augenverletzungen, thermischen und mechanischen Gefahren. Es ist jedoch wichtig zu beachten, dass PSA allein nicht ausreicht und durch Fachwissen, Fähigkeiten und die Einhaltung von Sicherheitsvorschriften ergänzt werden muss.

  • Arbeiten an Teilen, die unter Spannung stehen, sind strengstens untersagt. Vor Beginn der Arbeiten müssen geeignete Sicherheitsvorkehrungen getroffen werden, einschließlich des Freischaltens der Anlage.

  • Bei Schäden durch mangelhafte Elektroinstallation haftet der Errichter der Anlage gemäß den geltenden gesetzlichen Bestimmungen.

  • Diese Zusammenfassung von Richtlinien und Vorsichtsmaßnahmen ist nicht umfassend. Bei Unsicherheiten ist es ratsam, einen qualifizierten Elektriker zu konsultieren oder sich an örtliche Vorschriften und Bestimmungen zu halten, um maximale Sicherheit zu gewährleisten.

  • Die ordnungsgemäße Installation und Wartung von elektrischen Anlagen und Geräten ist von großer Bedeutung, um mögliche Gefahren zu minimieren und ein sicheres Umfeld zu schaffen.

weiterlesen...

 

 

Hier sind einige wichtige Begriffe aus der Elektrotechnik mit kurzen Erläuterungen:

Strom

Der Strom ist die elektrische Ladung, die pro Zeiteinheit durch einen elektrischen Leiter fließt. Er wird in Ampere (A) gemessen.

Spannung

Die Spannung ist die elektrische Potentialdifferenz zwischen zwei Punkten in einem elektrischen Stromkreis. Sie wird in Volt (V) gemessen und ist verantwortlich für den Stromfluss.

Widerstand

Der Widerstand ist ein Maß für die Fähigkeit eines Bauteils oder Leiters, den Stromfluss zu behindern. Er wird in Ohm (Ω) gemessen und folgt dem Ohmschen Gesetz.

Leistung

Die Leistung ist die Menge an Arbeit pro Zeiteinheit, die in einem elektrischen System verrichtet oder übertragen wird. Sie wird in Watt (W) gemessen und berechnet sich als das Produkt aus Strom und Spannung.

Ohmsches Gesetz

Das Ohmsche Gesetz besagt, dass der Strom durch einen elektrischen Leiter proportional zur angelegten Spannung und umgekehrt proportional zum Widerstand ist: I = U/R.

Kirchhoffsche Gesetze

Die Kirchhoffschen Gesetze sind grundlegende Prinzipien in der elektrischen Schaltungstechnik. Das erste Gesetz besagt, dass in einem Knotenpunkt eines Stromkreises die Summe der eingehenden Ströme gleich der Summe der ausgehenden Ströme ist. Das zweite Gesetz besagt, dass in einer geschlossenen Schleife die Summe der Spannungsabfälle gleich der Summe der Spannungsquellen ist.

Gleichstrom (DC)

Gleichstrom ist ein elektrischer Strom, bei dem die Richtung des Stromflusses konstant ist.

Wechselstrom (AC)

Wechselstrom ist ein elektrischer Strom, bei dem die Richtung des Stromflusses periodisch wechselt. In den meisten Haushalten und in der öffentlichen Stromversorgung wird Wechselstrom verwendet.

Frequenz

Die Frequenz ist die Anzahl der Perioden (Schwingungen) pro Zeiteinheit in einem periodischen Signal. In der Elektrotechnik wird sie in Hertz (Hz) gemessen.

Phasenverschiebung

Die Phasenverschiebung ist der zeitliche Unterschied zwischen zwei periodischen Signalen, die in der Regel sinusförmig sind. Sie wird in Grad oder Rad gemessen und gibt an, wie weit das eine Signal in Bezug auf das andere verschoben ist.

Schaltbild

Ein Schaltbild ist eine vereinfachte grafische Darstellung eines elektrischen Schaltkreises. Es zeigt die Komponenten und deren Verbindungen.

Kondensator

Ein Kondensator ist ein elektronisches Bauteil, das elektrische Ladung speichern kann. Er besteht aus zwei leitenden Platten, die durch ein Dielektrikum (Isolator) getrennt sind.

Korrespondierende Leiter

Korrespondierende Leiter sind zwei Leiter, die durch elektromagnetische Induktion miteinander verbunden sind, z.B. eine Primär- und eine Sekundärspule in einem Transformator.

Spule

Eine Spule ist ein Bauteil, das aus einer gewickelten Drahtwicklung besteht. Sie erzeugt ein magnetisches Feld, wenn Strom durch sie fließt, und kann in der Induktivität messbare Effekte haben.

Induktivität

Die Induktivität ist die Fähigkeit einer Spule, eine Spannung zu erzeugen, wenn sich der Strom durch sie ändert. Sie wird in Henry (H) gemessen und beeinflusst den Stromfluss in Wechselstromkreisen.

Kapazität

Die Kapazität ist die Fähigkeit eines Kondensators, Ladung zu speichern. Sie wird in Farad (F) gemessen und beeinflusst den Stromfluss in Wechselstromkreisen.

Transistor

Ein Transistor ist ein elektronisches Bauteil, das als Verstärker oder Schalter in Schaltungen verwendet wird. Es besteht aus Halbleitermaterial und kann den Stromfluss steuern.

Halbleiter

Ein Halbleiter ist ein Material, das eine elektrische Leitfähigkeit zwischen einem Isolator und einem Leiter aufweist. Halbleitermaterialien wie Silizium oder Germanium werden in der Elektronik verwendet.

Dioden

Eine Diode ist ein elektronisches Bauteil, das den Stromfluss nur in eine Richtung zulässt. Sie besteht aus einem Halbleitermaterial und wird oft als Gleichrichter eingesetzt.

Relais

Ein Relais ist ein elektromechanisches Schaltgerät, das einen elektrischen Stromkreis steuern kann. Es besteht aus einer Spule und einem Schalter, der durch die Spule betätigt wird.

Schalter

Ein Schalter ist ein elektronisches Bauteil oder Gerät, das den Stromkreis unterbrechen oder schließen kann, um den Stromfluss zu steuern.

Netzwerk

Ein Netzwerk ist eine Verbindung von elektrischen Komponenten, Bauteilen oder Schaltungen. Es kann verschiedene Topologien wie Serienschaltung oder Parallelschaltung aufweisen.

Transformator

Ein Transformator ist ein elektrisches Gerät, das die Spannung und den Strom in einem Wechselstromkreis ändern kann. Er besteht aus zwei oder mehr Spulen und nutzt die elektromagnetische Induktion.

Elektromagnet

Ein Elektromagnet ist ein Magnet, der durch den Stromfluss in einer Spule erzeugt wird. Er besteht aus einem Kernmaterial und einer Spule und wird in vielen Anwendungen wie Elektromotoren eingesetzt.

Impedanz

Die Impedanz ist der Gesamtwiderstand für den Stromfluss in einem Wechselstromkreis. Sie umfasst den Widerstand und die reaktive Komponente (induktive oder kapazitive).

Kurzschluss

Ein Kurzschluss tritt auf, wenn ein Leiter einen sehr geringen Widerstand aufweist und den Strom ungehindert fließen lässt. Es kann zu einer Überlastung führen und gefährlich sein.

Stromkreis

Ein Stromkreis ist ein geschlossener Pfad, durch den der elektrische Strom fließt. Er besteht aus einer Stromquelle, Verbrauchern und Verbindungen.

Serienschaltung

Eine Serienschaltung ist eine Verbindung von elektrischen Komponenten, bei der der Strom durch jeden Verbraucher denselben Pfad nimmt. Die Gesamtspannung teilt sich auf die Verbraucher auf.

Parallelschaltung

Eine Parallelschaltung ist eine Verbindung von elektrischen Komponenten, bei der der Strom sich aufteilt und durch jeden Verbraucher einen separaten Pfad nimmt. Die Spannung bleibt für jeden Verbraucher gleich.

Sicherung

Eine Sicherung ist ein Schutzbauteil, das in einem Stromkreis eingefügt wird, um vor Überstrom zu schützen. Bei zu hohem Stromfluss schmilzt die Sicherung und unterbricht den Stromkreis.

Überstromschutz

Der Überstromschutz ist ein Mechanismus oder eine Vorrichtung, die den Stromkreis vor Schäden durch übermäßigen Stromfluss schützt. Dies kann durch Sicherungen, Schutzschalter oder Relais erfolgen.

Erdung

Die Erdung ist eine Verbindung eines elektrischen Systems oder Geräts mit der Erde. Sie dient dazu, elektrische Ströme sicher abzuleiten und das Risiko von Stromschlägen zu verringern.

Frequenzumrichter

Ein Frequenzumrichter ist ein elektronisches Gerät, das die Frequenz eines Wechselstroms ändern kann. Er wird häufig in der Antriebstechnik eingesetzt, um die Geschwindigkeit von Elektromotoren zu regeln.

Elektromagnetische Verträglichkeit (EMV)

Die elektromagnetische Verträglichkeit befasst sich mit der Fähigkeit von elektrischen Geräten und Systemen, elektromagnetische Störungen zu verhindern und nicht von ihnen beeinflusst zu werden.

Verlustleistung

Die Verlustleistung ist die elektrische Leistung, die in einem Bauteil oder System in Form von Wärme verloren geht. Sie tritt aufgrund von Widerstand, Induktivität und Kapazität auf.

Kurzschlussstrom

Der Kurzschlussstrom ist der Strom, der durch einen Stromkreis fließt, wenn ein Kurzschluss auftritt. Er kann extrem hoch sein und muss bei der Dimensionierung von Schutzvorrichtungen berücksichtigt werden.

Leistungsfaktor

Der Leistungsfaktor ist das Verhältnis zwischen Wirkleistung (tatsächlich genutzte Leistung) und Scheinleistung (Produkt aus Strom und Spannung) in einem Wechselstromkreis. Er gibt an, wie effizient die elektrische Leistung genutzt wird.

Isolationswiderstand

Der Isolationswiderstand ist der elektrische Widerstand zwischen zwei Leitern, die durch eine Isolierung voneinander getrennt sind. Er gibt Auskunft über die Qualität der Isolierung und wird oft bei Sicherheitsprüfungen gemessen.


main version

Wir nutzen Cookies auf unserer Website. Einige von ihnen sind essenziell für den Betrieb der Seite, während andere uns helfen, diese Website und die Nutzererfahrung zu verbessern (Tracking Cookies). Sie können selbst entscheiden, ob Sie die Cookies zulassen möchten. Bitte beachten Sie, dass bei einer Ablehnung womöglich nicht mehr alle Funktionalitäten der Seite zur Verfügung stehen.