Connecting Telephone Sockets - Elektrotechnik von A - Z

Hauptmenü

  • Basic knowledge
    • The 5 Safety Rules
    • Dangers of Electrical Current
    • Correctly Wiring Junction Boxes
    • Polarity of Sockets and Couplings
    • Installation Cable Colors and their Specifications
    • Installations - Wires - Colors and their Meaning
    • IP Protection Rating
    • IP Protection Classes
    • Protective Measures
    • Electrical Engineering Terminology
    • Electrical Safety Guidelines and Precautions
  • Circuits
    • Two-Way Switching Circuit
    • Cost-Saving Two-Way Switching Circuit
    • Three-way Switch Circuit
    • Control Three-way Switch Circuit
    • Pushbutton Circuit
    • Dual Circuit of Fluorescent Lamps
    • Inductive Single Circuit of Fluorescent Lamps
    • Capacitive Single Circuit of Fluorescent Lamps
  • Contactor Circuits
    • Star-Delta Starting Contactor Circuit
    • Dahlander Contactor Circuits
    • Reversing Contactor Circuit
    • Self-latching Contactor Circuit
  • Switching Devices
    • Two-way switch
    • Series switch
    • Control-changeover switch
    • Three-way switch
    • Push button
    • Series push button
    • Motion Sensor
    • Dimmer
    • Timer Switch
  • Electrical Equipment
    • The Residual Current Device (RCD)
    • Connecting Electrical Outlets
    • Connecting plug / socket
    • Connecting Lamps
    • CEE Sockets
    • Electric stove in three-phase operation
    • Connecting Telephone Sockets
  • Testing and Measurements
    • Insulation Resistance Measurement
    • Loop Impedance Measurement
    • Residual Current Measurement (RCD Testing)
    • Voltage Measurement
    • Phase Sequence Measurement (in three-phase systems)
    • Protective Conductor Testing
 

Select your language

  • You are here:  
  • Homepage
  • ⇨
  • Electrical Equipment
  • ⇨
  • Connecting Telephone Sockets

Connecting Telephone Sockets Correctly

Instructions for Connecting Telephone Sockets

 

 

Preparation:
Gather the necessary tools, including a screwdriver (a Phillips screwdriver is ideal), cable cutters, and wire strippers.

Preparation of the Telephone Line:
Locate the end of the telephone line that will be connected to the telephone socket. Typically, there is a small plastic cover at the end of the line.
Carefully remove the plastic cover to expose the wires. Usually, you will find four wires: red, green, yellow, and black.

Connecting the Telephone Line:
Take the TAE telephone socket and open it by loosening the screws at the top and bottom of the cover.
Inside the telephone socket, you will find four terminal blocks or screw terminals labeled as: a, b, c, and d.
Take the red wire and connect it to terminal a. Loosen the screw terminal, insert the wire, and tighten the screw to establish a secure connection. Repeat this process for the other three wires: green to terminal b, yellow to terminal c, and black to terminal d.
Ensure that the wires are securely attached to the terminals and no wire is protruding.

Finishing:
Close the telephone socket by replacing the cover and tightening the screws at the top and bottom.
Double-check that all wires are properly attached to the terminals.
Test the telephone socket by connecting a telephone and verifying if you can establish a connection.

 

 
Overview of Telephone Sockets:

For a conventional telephone connection using a TAE socket, the incoming line is connected to terminals 1 and 2.

TAE Circuit Diagram

 

 

Double Connections:

For a double connection with TAE NFF, the first line is connected to the upper terminal block, and the second line is connected to the lower terminal block.

When devices are connected to an NFN socket, only one of them can be used at a time. When a device is plugged into an N socket and activated, the devices connected behind it are disconnected from the line. For example, if a conventional modem is active in the left N socket, the right N socket and the F socket are disabled.

The same applies to the left and middle sockets of an NFF socket. A modem in the N socket can disable the telephone in the middle socket but not the one in the right socket, as it is electrically independent of the other two sockets.

                               

TAE NFF Circuit Diagram                              TAE-F Circuit Diagram                          TAE-NFF Circuit Diagram     

 

 

 

TAE Socket System

In a TAE socket system, the incoming line is connected to terminals 1 and 2.

The additional pair of wires is connected from 6 to 1 and from 5 to 2.

It should be noted that when using an F-coded device, the rest of the socket system will be deactivated. If the system is intended to operate multiple N-coded devices as well as an F-coded device, the TAE-F socket must be connected at the end of the system.

 

                

TAE-NFN Circuit Diagram                                                                  Circuit                                     

 

 


main version

Wir nutzen Cookies auf unserer Website. Einige von ihnen sind essenziell für den Betrieb der Seite, während andere uns helfen, diese Website und die Nutzererfahrung zu verbessern (Tracking Cookies). Sie können selbst entscheiden, ob Sie die Cookies zulassen möchten. Bitte beachten Sie, dass bei einer Ablehnung womöglich nicht mehr alle Funktionalitäten der Seite zur Verfügung stehen.